Shrnutí obsahu

Strany 1 - 14 x 56 and 14 x 62 Models

1400 Series Granulators 14 x 56 and 14 x 62 Models Models Covered: WG, 1400, MT, TG Part Number: MAN-484249 Bulletin Number: GRN2-610

Strany 2

1400 Series Granulators Chapter 1: Safety 10 of 43 1-2 General Safety Regulations This machine uses knives for the performance of its intended use.

Strany 3 - Shipping Info

1400 Series Granulators Chapter 1: Safety 11 of 43 1-4 Warnings and Precautions Our granulators are designed to provide safe and reliable operation

Strany 4

1400 Series Granulators Chapter 1: Safety 12 of 43 ! ROTATION OF MOTORS: The correct rotating direction for the granulator motor is clearly marked

Strany 5 - Table of Contents

1400 Series Granulators Chapter 2: Functional Description 13 of 43 Chapter 2: Functional Description 2-1 Models Covered in This Manual This manual

Strany 6

1400 Series Granulators Chapter 2: Functional Description 14 of 43 2-3 Typical Features and Components Hopper The hopper is an upright enclosure bo

Strany 7 - Chapter 1: Safety

1400 Series Granulators Chapter 2: Functional Description 15 of 43 2-4 Safety Features Motor Starter A magnetic motor starter with control transfor

Strany 8

1400 Series Granulators Chapter 3: Installation 16 of 43 Chapter 3: Installation 3-1 Uncrating the Equipment The complete granulator, including ac

Strany 9

1400 Series Granulators Chapter 3: Installation 17 of 43 3-3 Electrical Connections Granulator controls (if ordered) are shipped separately for mou

Strany 10 - 1-3 Responsibility

1400 Series Granulators Chapter 3: Installation 18 of 43 3-4 Accessing the Cutting Chamber You will need to access the cutting chamber before initi

Strany 11

1400 Series Granulators Chapter 3: Installation 19 of 43 3-6 Initial Start-up This machine has been run under power and tested at the factory prio

Strany 12

1400 Series Granulators ii Write Down Your Serial Numbers Here For Future Reference: _________________________ _________________________ _____

Strany 13 - 2-2 General Description

1400 Series Granulators Chapter 4: Operation 20 of 43 Chapter 4: Operation 4-1 Start-up Before starting the machine, check that the rotor rotates

Strany 14

1400 Series Granulators Chapter 4: Operation 21 of 43 4-4 Shut-down Use the following procedure to properly and safely shut down the machine: 1. S

Strany 15 - 2-4 Safety Features

1400 Series Granulators Chapter 5: Maintenance 22 of 43 Chapter 5: Maintenance 5-1 Preventative Maintenance Schedule Check Frequency Knife cleara

Strany 16 - Chapter 3: Installation

1400 Series Granulators Chapter 5: Maintenance 23 of 43 5-3 Replacing and Adjusting the Knives During use, the clearance between the rotor knives a

Strany 17 - 3-3 Electrical Connections

1400 Series Granulators Chapter 5: Maintenance 24 of 43 Bed Knives We recommend that the same screws and washers be re-used only when the bed knives

Strany 18

1400 Series Granulators Chapter 5: Maintenance 25 of 43 5-5 Adjusting Belt Tension For continuous reliable operation of the granulator, it is impor

Strany 19 - 3-6 Initial Start-up

1400 Series Granulators Chapter 5: Maintenance 26 of 43 7. In no case should the belts be over tensioned, as this can significantly redu

Strany 20 - Chapter 4: Operation

1400 Series Granulators Chapter 5: Maintenance 27 of 43 5-6 Rotor Bearing Replacement Use the following procedure to remove and replace the rotor b

Strany 21 - 4-4 Shut-down

1400 Series Granulators Chapter 6: Troubleshooting 28 of 43 Chapter 6: Troubleshooting 6-1 Introduction The utmost in safety precautions should be

Strany 22 - Chapter 5: Maintenance

1400 Series Granulators Chapter 6: Troubleshooting 29 of 43 6-2 Electrical Faults Problem Possible Cause Possible Remedy Motor Fails to Start Supp

Strany 23

1400 Series Granulators iii Shipping Info Unpacking and Inspection You should inspect your granulator for possible shipping damage. Thoroughly chec

Strany 24 - 5-4 Sharpening the Knives

1400 Series Granulators Chapter 6: Troubleshooting 30 of 43 6-3 Processing Faults Problem Possible Cause Possible Remedy Stalling Overfeeding Redu

Strany 25 - 5-5 Adjusting Belt Tension

1400 Series Granulators Chapter 6: Troubleshooting 31 of 43 6-4 Mechanical Faults Problem Possible Cause Possible Remedy Bearing overheating Exces

Strany 26

1400 Series Granulators Chapter 7: Appendix 32 of 43 Chapter 7: Appendix 7-1 Recommended Torque for Screws (Grade 8 alloy steel heat-treated scre

Strany 27

1400 Series Granulators Chapter 7: Appendix 33 of 43 7-2 Technical Specifications Features Model Throat Size Cutting Circle Diameter Throughput App

Strany 28 - Chapter 6: Troubleshooting

1400 Series Granulators Chapter 7: Appendix 34 of 43 7-3 Drawings Dimensions (14 x 56 model)

Strany 29 - 6-2 Electrical Faults

1400 Series Granulators Chapter 7: Appendix 35 of 43 7-4 Pneumatic Hopper Actuator Assembly The pneumatic cylinder actuators are used to open the h

Strany 30 - 6-3 Processing Faults

1400 Series Granulators Chapter 7: Appendix 36 of 43 Closing the Tilt Plate and Hopper Use the following procedure to close the hopper: 1. Be sure

Strany 31 - 6-4 Mechanical Faults

1400 Series Granulators Chapter 7: Appendix 37 of 43 Pneumatic Actuator Assembly Typical Wiring Diagram

Strany 32 - Chapter 7: Appendix

1400 Series Granulators Chapter 7: Appendix 38 of 43 7-5 Feed Roll Assembly The two counter-rotating pinch rolls in the feed roll assembly control

Strany 33

1400 Series Granulators Chapter 7: Appendix 39 of 43 Cleaning the Feed Roll Assembly Disconnect the main air line and electrical power. For normal

Strany 34 - 7-3 Drawings

1400 Series Granulators iv Returns Do not return any damaged or incorrect items until you receive shipping instructions from the shipping departm

Strany 35

1400 Series Granulators Chapter 7: Appendix 40 of 43 Feed Roll Assembly Spare Parts List (14 x 56 Model) Quantity Name Part Number 2 Brg Stationary

Strany 36

1400 Series Granulators Chapter 7: Appendix 41 of 43 7-6 Load Sensing System The granulator load sensing system stops the feed roll motor and turns

Strany 37

1400 Series Granulators Chapter 7: Appendix 42 of 43 7-7 Technical Assistance Parts and Service Department The ACS Customer Service Group wi

Strany 38 - 7-5 Feed Roll Assembly

1400 Series Granulators Chapter 7: Appendix 43 of 43

Strany 39

1400 Series Granulators v Table of Contents CHAPTER 1:! SAFETY ... 7!1-1! How to Use T

Strany 40

1400 Series Granulators vi 5-6! Rotor Bearing Replacement ... 27

Strany 41 - 7-6 Load Sensing System

1400 Series Granulators Chapter 1: Safety 7 of 43 Chapter 1: Safety 1-1 How to Use This Manual Use this manual as a guide and reference for instal

Strany 42 - 7-7 Technical Assistance

1400 Series Granulators Chapter 1: Safety 8 of 43 Figure 1: Belt Tensioning Information Hazard Alert Symbol Description/Explanation Preventative Ma

Strany 43

1400 Series Granulators Chapter 1: Safety 9 of 43 Mandatory Symbol Description/Explanation Read Operators Manual. This equipment must be operated